Water Chiller

A water chiller is a device that reduces the temperature of water. The majority of chillers use refrigerant in a closed loop system to transfer heat from water to refrigerant, which is then pumped to a location where waste heat is released into the atmosphere. There are, however, several approaches to this problem. In hydroponics, pumps, illumination, and ambient heat can boost reservoir water temperatures, creating plant root and health problems. For maximum plant health, a chiller can be used to lower the water temperature below ambient; 68°F (20°C) is a healthy temperature for most plants. This promotes proper root growth and nutrient absorption.

Chilled water is extensively used in air conditioning to cool a building’s air and equipment in circumstances when multiple distinct rooms must be managed individually, such as a hotel. Before being delivered to the chilling area, the water is chilled to between 40 °F (4 °C) and 45 °F (7 °C) in a chiller. How to choose the correct chiller for the bathroom?

Because each industrial environment is unique, Dana created a 6-step guide to assist you in selecting the right chiller for your needs:

  • Determine the Heat Load

It’s crucial to figure out how much heat your application generates so that the chiller you choose is big enough for the job. There are various methods for determining the heat load (in BTU), but knowing the process is critical for accurate heat load calculations.

  • Determine the kind of coolant used, as well as the temperature and flow rate.

Once the heat load has been estimated, the next step is to determine the coolant, its target temperature, and the flow rate that the chiller must provide to the process. This is determined by the mechanism by which heat is transferred from the process to the coolant, as well as the type of coolant used. Water, for example, differs from oil in terms of its qualities.

  • Recognize the Installation Setting

In what kind of environment will the chiller be installed? Indoor applications, for example, may be subjected to high temperatures and polluted environments, whilst outdoor installations may be subjected to both low and high ambient temperatures. This can have an impact on chiller size and necessitate the use of accessories like air filters and sump warmers.

 

  • Use Chiller performance curves

Now, based on the chilled water supply temperature and the highest projected ambient air temperature, utilise the chiller performance curves to pick a chiller model that meets or exceeds the necessary capacity. To optimise the value of the chiller selection, the application’s safety margin should be considered in relation to available frame sizes.

 

  • Check Pump performance curves

 

Check the pump performance curves to make sure the pump will deliver adequate pressure at the design flow rate to meet the application’s requirements. Small coolant flow pathways or longer lengths in some liquid-cooled systems might result in higher-than-average pressure losses.

 

  • Final Selection

Finally, make sure that the standard Dana water chiller meets the remaining application criteria, such as power characteristics, control choices, footprint, agency listing, colour, and so on. Choosing a standard chiller will provide you with higher dependability, easier service, and worldwide support.Dana has a wide variety of packaged chillers to meet the needs of most applications. These packed chillers are ready to use and only require pipe and power to install as part of your process cooling solution – we’ll even supply the coolant. Ethylene and Propylene Glycol coolants are offered in a range of package choices, including full strength and pre-mixed. Each chiller model comes with the pump, tank, refrigeration system, and controls needed for easy installation and effective operation.

 

About us:

Established in 2001,DANA WATER HEATERS & COOLERS FACTORY LLC,is one of the manufacturing concerns of prestiguous DANA GROUP [www.danagroups.com] . Since it’s inception the company has endeavored to provide premium quality heating,cooling & refrigeration solutions to it’s valuable clients.

With it’s head office situated  within 10 minutes from Dubai International Airport,and it’s manufacturing faciltiies in Al Quoz Industrial Area 1 (Dubai) & Al Jurf Industrial Area (Ajman),we are fully equipped to meet the demands of the GCC,Gulf & Arab markets.

Our firm is an experienced Manufacturer, Exporter, and Supplier of Industrial Air Cooled Water Chillers,Tank Water Cooling System(Tank Water Chiller),Stainless Steel Drinking Coolers,Heaters,Swimming Pool Heat Pumps & Cold Room Refrigeration Solutions from Dubai, U.A.E. Our Units are designed to be highly efficient, consume less power and deliver reliable output. We are capable of delivering any order with reliability,on-time delivery & prompt after sales service. Dana Group has been catering to Dairy chiller and coldroom industry, Poultry Farm chiller and coldrooms, Livestock production coldrooms and water chillers, Hydroponic farm water chillers and coldrooms.

Customers can obtain our exclusive collection of heating & cooling solutions at modest rates. The Products we offer are acclaimed for their elegant designs, good spaciousness, and excellent finish. As a reliable Manufacturer, Exporter, and Supplier from Dubai, U.A.E., we ensure customers get a quality assured product. Hence, our quality auditors check our products on various parameters before the final delivery.Our products are exported to Africa,Oman (Ibri, Salalah, Muscat, Sohar, Nizwa, Barka),Bahrain,Saudi Arabia,Kuwait,Qatar ,Jordan and other neighboring Gulf/GCC Countries .We have our dedicated installation & after sales team to cover installations across UAE( i,e Dubai,Ajman,Sharjah,Al Ain ,Abu Dhabi,Fujairah,Ras Al Khaimah,UAQ) and GCC countries including Oman (Salalah, Muscat, Sohar, Nizwa, Barka, Ibri)

Dana Water Heaters And Coolers Factory LLC

Contact Person : Mr. Ankur Singh
Address :-Head Office – Suite No 405-406,B-Block Centurion Star Bldg,Opp Deira City Center, Dubai – 40743, United Arab Emirates

Factory – Plot # 369-B166,Al Quoz Industrial Area #4,Dubai , UAE

Contact No. : +971-4-2217273 (Landline)
Email : info@danagroups.com / info@danawatercoolers.com