DANA Cooling manufactures air-cooled industrial water chillers in Dubai — ISO 9001:2015 certified, built for UAE ambient conditions. Ready stock from 2 TR. Custom configurations above 100 TR.
Request Industrial Quote Technical team responds within 1 business hour
Industrial Water Chiller UAE — Air-Cooled Process Chillers 2–100 TR
DANA Cooling manufactures industrial water chillers in Dubai for process cooling, food and beverage production, plastics manufacturing, HVAC supplementation, and commercial cooling loads across the UAE and GCC. Our industrial DC series spans 10 TR (DC 10000) to 50 TR (DC 50000) as standard models, with custom configurations available beyond 100 TR. All units are air-cooled, UAE-manufactured, ISO 9001:2015 certified, and available from ready stock.
For plant engineers and procurement teams operating in the UAE’s extreme summer climate, local manufacture means shorter lead times, accessible spare parts, and service engineers who understand the 50°C+ ambient conditions your equipment operates in.
Industrial Chiller Applications in the UAE
Process water cooling is required in a wide range of industries operating across Dubai, Abu Dhabi, Sharjah, and the northern emirates. DANA industrial water chillers are deployed in:
- Plastics and rubber manufacturing: Injection moulding, blow moulding, and extrusion lines require precise mould cooling — typically 10–20°C supply water temperature — to maintain cycle times and part quality
- Food and beverage production: Fermentation vessels, pasteurisers, and bottling lines require consistent chilled water for process temperature control and CIP (clean-in-place) systems
- Printing and packaging: Web offset presses and laminating lines generate high heat loads requiring process water cooling at 15–25°C
- Chemical and pharmaceutical manufacturing: Reactor cooling and crystallisation processes require stable supply water temperatures across shifts
- HVAC supplementation: Data centres, large commercial buildings, and hospitality properties requiring supplementary chilled water capacity
- Metal working and CNC machining: Cutting fluid cooling and spindle cooling on high-speed machining centres
DANA Industrial DC Series — Specifications
All industrial models are air-cooled, meaning no cooling tower is required. This reduces installation complexity and eliminates the legionella risk associated with open-circuit water-cooled systems — a significant advantage for UAE facilities with limited space or strict hygiene protocols.
| Model | Cooling Capacity (TR) | Cooling Capacity (kW) | Typical Application |
|---|---|---|---|
| DC 10000 | 10 TR | 35 kW | Small process plant, light industrial |
| DC 15000 | 15 TR | 52 kW | Medium production line, F&B |
| DC 20000 | 20 TR | 70 kW | Plastics moulding, chemical reactor |
| DC 25000 | 25 TR | 88 kW | Multi-line manufacturing |
| DC 30000 | 30 TR | 105 kW | Large F&B or printing facility |
| DC 35000 | 35 TR | 123 kW | Heavy industrial process |
| DC 40000 | 40 TR | 140 kW | Large-scale process cooling |
| DC 45000 | 45 TR | 158 kW | Industrial complex, HVAC supplement |
| DC 50000 | 50 TR | 175 kW | Large industrial plant |
For requirements above 50 TR, DANA supplies customised chilling plant configurations up to 100 TR and beyond. Contact our technical team with your process heat load, required supply and return temperatures, and ambient conditions.
Why Air-Cooled Chillers Are the Preferred Choice in the UAE
The UAE presents a specific set of engineering constraints for industrial cooling:
- No cooling tower required: Air-cooled chillers reject heat directly to ambient air via condenser fans. This eliminates the capital cost, maintenance burden, and water consumption of an evaporative cooling tower — critical where UAE water tariffs are significant and space is limited
- High-ambient design: DANA industrial chillers are designed to operate at ambient temperatures up to 52°C. Standard chillers from temperate markets are typically rated to 35–40°C ambient and will derate or trip in UAE summer — DANA units are built for local conditions from the start
- No water treatment programme required: Closed-loop air-cooled systems require only glycol inhibitor and pH management — far simpler than open cooling tower chemistry management
- Ready for GCC export: DANA industrial chillers are already deployed in Oman, Bahrain, Kuwait, Saudi Arabia, Jordan, and African markets — the same units available for UAE projects
Key Technical Features — DANA Industrial DC Series
- Refrigerant: R-410A or R-407C (confirm model-specific at time of order)
- Compressor type: Scroll or reciprocating, depending on capacity
- Heat exchanger: Shell and tube, designed for low-fouling process water
- Condenser: Copper-aluminium fin coil with high-static-pressure condenser fans
- Controls: Microprocessor controller with digital temperature display, high/low pressure protection, and anti-freeze protection
- Supply water temperature range: 5°C to 25°C (standard configurations)
- Frame: Powder-coated galvanised steel — suitable for outdoor rooftop placement without additional weatherproofing
- Certification: ISO 9001:2015 (DANA factory)
Procurement and Lead Times for UAE Industrial Buyers
DANA holds buffer stock of standard DC series models in Dubai. For models DC 10000 to DC 25000, typical delivery from order confirmation is 3–7 working days within the UAE. For DC 30000 to DC 50000 and custom configurations, allow 2–4 weeks for build and test. All units are factory-tested before dispatch.
DANA can provide:
- Technical datasheets and performance curves for tender submission
- Site-specific capacity calculations based on process heat load
- Installation and commissioning support across the UAE
- Annual maintenance contracts
- Spare parts supply from Dubai stock
For residential tank or pool cooling requirements, see the water tank chiller UAE page. For city-specific delivery information in Dubai and Abu Dhabi, see our water chiller Dubai and Abu Dhabi page.
Frequently Asked Questions — Industrial Water Chiller UAE
What is the difference between a process chiller and a standard air conditioner?
A process chiller cools water (or a water-glycol mix) in a closed loop to a precise set point — typically 5–25°C — for use in industrial processes. A standard air conditioner cools air inside a space. Process chillers are designed for continuous duty, precise temperature control, and compatibility with industrial cooling loads. They are not interchangeable with HVAC equipment.
How do I calculate the chiller size I need for my production process?
Chiller sizing requires three inputs: process heat load in kW (or BTU/hr), required supply water temperature (°C), and maximum return water temperature. Your machinery supplier or plant engineer should provide these figures. DANA’s technical team can assist with the calculation if you provide machine specifications and daily run hours. As a cross-check: 1 TR = 3.517 kW of heat removal.
Can DANA industrial chillers operate in 50°C ambient temperature?
Yes. DANA DC series industrial chillers are designed for UAE ambient conditions and are rated to operate at ambient temperatures up to 52°C. Units are specified with high-ambient condensers — not standard-market units rebranded for the region. This is a critical spec to confirm with any chiller supplier before purchase.
What refrigerant do DANA industrial chillers use?
DANA DC series models use R-410A or R-407C refrigerant depending on the specific model. Both are non-ozone-depleting HFC refrigerants. Confirm the exact refrigerant at time of order to ensure compatibility with your site’s refrigerant handling certification.
Does DANA supply industrial chillers outside Dubai — Abu Dhabi, Sharjah, or northern emirates?
Yes. DANA supplies and installs industrial water chillers across all seven UAE emirates including Abu Dhabi, Dubai, Sharjah, Ajman, Fujairah, Ras Al Khaimah, and Umm Al Quwain. DANA also exports to GCC countries including Oman, Bahrain, Kuwait, Saudi Arabia, and Jordan, as well as African markets.
Can DANA provide a chiller on a rental or short-term basis?
Contact DANA directly to discuss rental or temporary cooling arrangements for specific project needs. Standard commercial terms apply to outright purchase with 3–7 day delivery for stock models. Contact the team at danawatercoolers.com/contactus for current availability.
Request a Technical Quotation
To receive a quotation for an industrial water chiller in the UAE, send the following to DANA’s technical team:
- Required cooling capacity (TR or kW)
- Supply and return water temperatures required
- Installation site location and ambient temperature max
- Available power supply (voltage, phase, Hz)
- Any specific refrigerant, certification, or footprint requirements
Submit your requirements at danawatercoolers.com/contactus
For smaller domestic and villa applications, see the water tank chiller UAE page.